1. LCD Initial Data Input (1)

Mode
Signal
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: B, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
3A
59
3B
00
3C
04
Fixed data
3D
5B
3E
00
3F
02
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
PLAY
Arbitrary
B
3A to 3F
Remark

2. LCD Initial Data Input (2)

Mode
Signal
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
CE
A2
CF
B7
D0
AD
D1
7E
D2
99
D3
75
D4
B7
D5
3C
D6
6E
D7
93
D8
61
D9
97
DC
46
DD
6F
DE
C6
DF
B7
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
5-30
Ver. 1.2 2001. 08
PLAY
Arbitrary
D
CE to D9, DC to DF
Remark
Fixed value
Bright adjustment
Color adjustment
White blance adjustment
Contrast adjustment
D range adjustment
V-COM level adjustment
VCO adjustment (NTSC)
V-COM adjustment
Fixed value