3. Flange Back Check

Mode
Subject
Measurement Point
Measuring Instrument
Specified value
Checking method:
Order Page Address Data
1
2
0
01
01
3
4
5
6
6
2C
01
7
Processing after Completing Adjustment:
Order Page Address Data
1
6
2C
00
2
3
0
01
00
CAMERA
Siemens star chart
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Check operation on the LCD
screen
Focused at the TELE end and
WIDE end
Procedure
Place the Siemens star 1.0 m
from the front of the lens.
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
Perform "Data setting during
camera system adjustments".
(Refer to page 5-14)
Shoot the Siemens star chart
with the zoom TELE end.
At this time, the center of
Siemens star chart should be
in the center of the LCD
screen.
Check that the lens is
focused.
While observe the LCD
screen, change the zoom to
the WIDE end and check that
the lens is focused.
Procedure
Release the data setting
performed at step 3.
(Refer to page 5-14)