High Temperature Limit Switch
The high temperature limit switch is located in-
side the upper right hand corner of the firebox.
This feature will prevent the fireplace from
operating at abnormally high temperatures.
The burner will automatically turn off without
interrupting the pilot flame; the limit switch will
lock out and must be reset manually. To reset
the limit switch:
1. Turn off the burner by turning the gas con-
trol knob clockwise to the off position.
2. Remove limit switch plate by removing
two screws.
VRE3036ZMN Series
• Rating (Variable): 28,000/41,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
VRE3036ZMP Series
• Rating (Variable): 32,000/41,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
WARNING: Fireplace must be operated only with doors fully open.
ELECTRICAL WIRE CONNECTION WILL
REQUIRE MALE TO MALE CONNECTORS
OPTIONAL
ON/OFF
SWITCH
16
SAFETY DEVICE

SPECIFICATIONS

*For purpose of input adjustment

WIRING DIAGRAM

TO PILOT
OPTIONAL
REMOTER
RECEIVER
www.SuperiorFireplaces.US.com
3. Carefully pull limit plate out and press the
reset button.
4. Mount limit switch plate back using two
screws previously removed.
5. Re-light the burner following instructions
on page 12.
WARNING: Only a qualified
service person should service
the fireplace.
VRE3042ZMN Series
• Rating (Variable): 32,000/47,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (inches of water):
Max. 10.5" W.C., Min. 5.0" W.C.*
• Air Shutter: 3/16 OPEN
VRE3042ZMP Series
• Rating (Variable): 35,000/45,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (inches of water):
Max. 14" W.C., Min. 11" W.C.*
• Air Shutter: FULLY OPEN
HEAT LIMIT SWITCH
BLACK
BLACK
TPTH
TP
WHITE
TH
CONTROL
VALVE
INCOMING
MAIN GAS
SUPPLY