Fitting The Mechanical And Digital Time Clocks - Ariston C Operating Instructions Manual

Type c boilers
Table of Contents

Advertisement

13. Electrical Connections
13.1

Fitting the Mechanical and Digital Time Clocks

To fit the integral time clock it is necessary to proceed as follows;
(this should only be carried out by a competent engineer)
-
Isolate the electical supply to the appliance;
-
Remove the front panel as described in Section 18.1.1;
-
Remove the plastic cover on the right hand side (Fig. 34)
and pull out the 4 wires (Fig. 35);
N
: T
OTE
HE WIRES MAY BE TUCKED BEHIND THE ELECTRICAL COVER
-
Connect the time clock wires as follows;
M
M
(Fig. 36)
ECHANICAL
ODEL
Red Wire
-
Contact 1
Black Wire
-
Contact 2
Black Wire
-
Contact 3
Grey Wire
-
Contact 5
N
: T
OTE
HE TWO BLACK WIRES ON
D
M
(Fig. 37)
IGITAL
ODEL
Red Wire
-
Contact 1
Black Wire
-
Contact 2
Grey Wire
-
Contact 3
N
: S
B
W
OTE
ECOND
LACK
IRE IS NOT CONNECTED
-
Push the clock back into the panel and refit the casing
panel (Fig. 38).
Fig. 36
5 4 3
G
C
2 & 3
ONTACTS
CAN BE REVERSED
.
2
1
R
B
Fig. 38
(continued)
.
Fig. 34
Fig. 35
Fig. 37
29