3.2.12 Removing the Power Supply Unit / PBS Thermistor
Prerequisite conditions: 3.2.3/3.2.4/3.2.8/3.2.7 (right speaker)
Power Supply Unit
1. Remove the screw from the sensor shield plate, then pull it out.
2. Remove 2 screws from the case holding plate, then pull the case holding plate straight
up.
Cable Connector
3. To pull out the power cable connector for the lamp, remove the screw and washer
mounting the connector.
4. Disconnect 2 wire cables connected to the safety switch.
5. Disconnect the cable connector (black/white) connected to the power supply unit.
Screws
Figure 3-24
Power Cables
Safety Switch
Figure 3-25
Case Holding Plate
Screw
3-20
Sensor Shield Plate