CS-V18DKE CU-V18DKE / CS-V24DKE CU-V24DKE
2.2.
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote
control cannot be used.
• Press for ≥ 5 second to operate Cooling
operation mode and compressor force to on
("beep" sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for ≥ 5 second to enter various
setting mode. "beep, beep" sound will be
heard. (Used to toggle remote control signal
receiving sound or select remote control
transmission code).
Operation Indication Lamps (LED)
•
(Green) ............. Lights up in operation,
POWER
•
(Orange) ............ Lights up in Timer
TIMER
•
(Orange) ............. Lights up in Quiet
QUIET
•
POWERFUL
•
ION
(Green) .................. Lights up in Ionizer
•
SUPER
ALLERU-BUSTER
Operation Mode
• Cooling, Soft Dry and Automatic Operation.
Powerful Operation
• Reaches the desired room temperature
quickly.
Timer Operation
• Delay OFF/ON Timer control.
blinks in Automatic
Operation judging.
Setting.
Operation.
(Orange) ...... Lights up in Powerful
Operation.
Operation.
(Blue) ... Lights up in operation.
Quiet Operation
• To provide quiet operation.
Ionizer Operation
• Generate and discharge negative ion.
Random Auto Restart Control
• Unit will be restarted, when resume from
power failure, at previous setting.
Anti-Freezing Control
• To prevent indoor heat exchanger from
freezing.
Indoor Fan Speed Control
• Manual control fan speed (High, Medium and
Low).
• Automatic fan speed.
Airflow Direction Control
• Vertical airflow control can be adjusted
automatically or manually by remote control.
• Horizontal airflow control can be adjusted
automatically or manually by remote control.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• To reduce the built up humidity inside the
room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
4