8.4.7.
Anti-Dew Formation Control
• Purpose is to prevent dew formation on indoor unit air discharge area.
• The following conditions occur for 30 minutes continuously, anti-dew formation will activate:
− Remote Control setting temperature is less than 25°C.
− Compressor is on.
− Cooling operation mode.
− Indoor fan motor operate at low fan speed or QLo.
• This control is cancelled immediately when above condition is changed.
• Anti-Dew formation is control by:
1. Lo fan speed
Lo fan is changed to Lo+ fan
2. QLo fan speed
8.5.

Indoor Fan Speed Control

• Indoor Fan Speed can be set using remote control.
8.5.1.
Fan Speed Rotation Chart
Speed
Cool, Dry
S Hi
Hi
Me
Lo+
Lo
Lo-
S Lo
Q Hi
Q Me
Q Lo
CS-V24DKE
1590
1530
1390
1330
1250
1100
860
1430
1290
1150
20
CS-V18DKE
1420
1360
1250
1220
1150
980
780
1260
1150
1050