Powerful Operation; Quiet Operation - Panasonic CS-V18DKE Service Manual

Air conditioner
Table of Contents

Advertisement

CS-V18DKE CU-V18DKE / CS-V24DKE CU-V24DKE
8.9.

Powerful Operation

• The Powerful operation is to achieve the setting temperature quickly.
(Cooling and Soft Dry Operation condition)
• When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
setting temperature (Lower temperature limit: 16°C).
• This operation automatically will be running under SHi Fan Speed (Cooling).
• Vertical Airflow Direction:-
- In "Manual" setting, the vane will automatically shift down 10° lower than previous setting.
- In "Auto" setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
• Powerful operation stops when:-
− Powerful operation has operate for 15 minutes.
− Powerful button is pressed again.
− Quiet button is pressed.
− Stopped by OFF/ON operation button.
− Timer OFF activates.
− Operating mode is changed.

8.10. Quiet Operation

• The Quiet operation is to provide quiet cooling/heating operation condition compare to normal operation.
(Cooling and Soft Dry Operation condition)
• Once the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
2 dB(A) for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present sound level operation.
• Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo
+ 100 rpm). After that, it goes back to QLo +180 rpm (However Quiet LED remains on).
• Manual Fan Speed:-
− RPM control during Lo cool
− RPM control during Hi & Me cool