Panasonic DMR-ES35VP Service Manual page 27

Table of Contents

Advertisement

<Supplementary Data 4> (LM Information)
Result of request of driving Loading Motor.
Display
1
There was no change of mechanism position. (Loading Motor was OFF)
2
There was some change of mechanism position. (Loading Motor was ON)
7.2.5.
(VHS) Description of Self Diagnosis Memory
In this Self-Diagnosis Function, in case error has occurred continuously, maximum of the newest 3 error data are
memorized.
And in order to analyze cause of error, the error number and the supplementary data of mode, mechanism position and
so on are memorized.
7.2.5.1.
(VHS) Error Number and Supplementary Data
The Supplementary Data as shown below are memorized to each error number.
Error No.
01
The cylinder could not be started.
(Error of the cylinder or the cylinder driver.)
02
The CAP FG could not be detected.
03
Mechanism lock during without the unloading and the
cassette-up.
04
Mechanism lock during unloading
05
S-reel pulse cannot be detected when a cassette
tape is inserted.
(Error of the S-reel system or the Capstan system.)
06
Mechanism lock during the Cassette-up.
07
The recording circuit can not be operated in REC
mode.
08
The recording circuit is operated in except for REC
mode.
09
Serial
communication
Microprocessor (IC6001) and Timer Microprocessor
(IC7501).
11
Cylinder clogs during the PLAY mode.
15
S-reel pulse cannot be detected when a cassette
tape is inserted.
(Error of the S-reel system or the Capstan system.)
16
Detection of the Cylinder lock during the constant
rotation
17
Detection of S-reel lock during the constant tape
running
18
Detection of T-reel lock during the constant tape
running
20
NG1 in the PG Shifter Automatic Adjustment
(The cylinder rotation is unstable during the
automatic adjustment.)
21
NG2 in the PG Shifter Automatic Adjustment
(The vertical sync signal is lacked while over 5
seconds on the alignment tape.)
22
NG3 in the PG Shifter Automatic Adjustment
(The installing position of Heads to the cylinder is our
of specification.)
23
NG4 in the PG Shifter Automatic Adjustment
(The servo is not locked to the cylinder for more than
10 sec.)
80
An exceptional ejection depends on a Error
Note 1: Details of "VHS mode" of the Supplementary Data 1 (These values are hexadecimal indication)
0: STOP, 1: EJECT, 2: REW, 3: FF, 4:REV, 5: CUE, 6: SLOW, 7: POWEROFF, 8: PLAY, 9: STIL,
A: REC, B: REC PAUSE, C: ADUB, D: ADUB PAUSE, E: INSERT, F: INSERT PAUSE
Note 2: Explanation of "Tape position" of the Supplementary Data
The Tape position Data is the area data of S-reel that is used for judgment of reducing speed in the Main microprocessor
IC6001, and as the tape position is moved from the starting edge to the finishing edge, the value becomes smaller.
The Tape Data does not become "0" even if the tape reaches the finishing edge as the hub remains, and the tape position
values are different between the large hub and the small hub as the each diameters are different from each other.
Reason
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
Error
between
VHS
-
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
VHS mode
Description
Supplementary Data
Data 1
Data 2
-
-
Standby position
-
Tape position
Standby position
-
-
-
-
Value of S-Reel Pulse
counted
Tape position
Tape position
Tape position
-
-
-
-
Refer to *Note 3
27
DMR-ES35VP / DMR-ES35VPC
Data 3
Data 4
-
-
Process No.
Number of FG
Process No.
LM information
Process No.
LM information
Process No.
LM information
Process No.
LM information
Process No.
-
Process No.
-
-
-
Process No.
-
Process No.
-
Process No.
-
Process No.
Number of FG
Process No.
Number of FG
Process No.
-
Process No.
-
Process No.
-
Process No.
-
Process No.
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmr-es35vpc

Table of Contents