Panasonic DMR-ES35VP Service Manual page 25

Table of Contents

Advertisement

Service
Contents
Number
2
Indication for the
inner
data
of
IC6001
3
Self-diagnosis
history (1st)
4
Self-diagnosis
history (2nd)
5
Self-diagnosis
history (3rd)
6
Indication for the
inner
data
of
IC6001
7
Manual mechanism
operation
7.2.3.2.
Example of FIP
7.2.4.
(VHS) Self-Diagnosis History Memory Function
7.2.4.1.
(VHS) Condition for memorizing of the self-diagnosis history
1. The self-diagnosis result and the supplementary data are the condition memorized just as an Error is detected.
2. There are the histories from number 1 to number 3.
3. The latest Error is memorized on history number 1,and then the old histories are shifted to the history number 2, 3.
4. Put out data from the memory number 3 by the shift is deleted.
5. If the latest Error is same with the history number 1 (2nd-latest), it is not memorized.
(The same Error number is not memorized in succession)
Contents of Indication on minute
Mechanism position
(Real time)
0L: EJECT position
02: DOWN position
03: RREW position
04: LOAD position
05: REV position
06: PLAY position
07: POFF position
08: STOP_R position
09: STOP_F position
- : FF/REW position
- : Intermediate between
each positions
Error number of history 1
Error number of history 2
Error number of history 3
Real time servo data (4 digits)
(Real time)
Higher rank 1 BYTE of SERVO data Lower rank 1 BYTE of SERVO data
Real time mechanism position
0L: EJECT position
02: DOWN position
03: RREW position
04: LOAD position
05: REV position
06: PLAY position
07: POFF position
08: STOP_R position
09: STOP_F position
- : FF/REW position
- : Intermediate between
each positions
Contents of Indication on second
Ordering for the Motors
(Real time)
0*, 2*: CYL off,
CAP off
1*: CYL off,
CAP on (fwd)
3*: CYL off,
CAP on (rev)
8*, A*: CYL on,
CAP off
9*: CYL on,
CAP on (fwd)
B*: CYL on,
CAP on (rev)
*0: Motor off
*1: Loading
*2: Unloading
*3: Break (Load + Unload)
Supplementary data 1 and 2 of
history 1.
Supplementary data 1 and 2 of
history 2.
Supplementary data 1 and 2 of
history 3.
Real time ordering for the Motors
0*, 2*: CYL off,
CAP off
1*: CYL off,
CAP on (fwd)
8*, A*: CYL on,
CAP off
9*: CYL on,
CAP on (fwd)
B*: CYL on,
CAP on (rev)
*0: Motor off
*1: Loading
*2: Unloading
*3: Break (Load + Unload)
25
DMR-ES35VP / DMR-ES35VPC
Remarks
There are next conditions in this
mode for enable the mechanism
operations without a cassette tape.
The starting / finishing edges are
not detected.
The reel lock is not detected
The tape and the positions are not
detected.
, And so on.
Press the EJET key for over 3
seconds in this mode, and then the
VCR is shifted into the special
modes, such as PG Adjustment,
Model Code Setting, and so on.
The orders for the motors are as
follows.
Bit 7: CYL ON/OFF
Bit 6: ------------------
Bit 5: CAP FWD/REV
Bit 4: CAP ON/OFF
Bit 3: ------------------
Bit 2: ------------------
Bit 1: UNLOADING(H)
Bit 0: LOADING(H)
In the Self-Diagnosis Memory, next 3
BYTE is memorized for an Error.
1 BYTE: Its Error number
2 BYTE: Its supplementary data
In these modes, the supplementary
data 3 and 4 instead of the Error
number and supplementary data 1
and 2 are indicated only while
pressing STOP key.
Press the STOP key, and then the
cassette tape is unloaded.