T-4-30
Setting Description
Normal Operation
Single-Sided Intermittent Feed
Press the push switch SW2 on the ADF controller PCB; thereafter, each press on the push
switch SW2 will send the original intermittently.
Double-Sided Intermittent Feed
Press the push switch SW2 on the ADF controller PCB; thereafter, each press on the push
switch SW2 will send the original intermittently.
Belt Motor (M2) Drive
Press the push switch SW2 on the ADF controller PCB to start it; another press will stop
it.
The operation will be as follows, executed automatically:
CW (700 -> 520 -> 260 -> 30 mm/sec) ->
CCW: 700 -> 520 -> 260 -> 130 mm/sec).
Reversal Motor (M1) Drive
Press the push switch SW2 on the ADF controller PCB to start it; another press will stop
it.
The operation will be as follows, executed automatically:
CW (700 -> 520 -> 260 -> 130 mm/sec) ->
CCW (700-> 520 -> 260 -> 130 mm/sec).
Delivery Motor (M5) Drive
Press the push switch SW2 on the ADF controller PCB to start it; another press will stop
it.
The operation will be as follows, executed automatically: CW (700 -> 520 -> 260 -> 130
mm/sec) -> CCW (700 -> 520 -> 260 -> 130 mm/sec).
Pickup Motor (M3) Drive
Press the push switch (SW2) on the ADF controller PCB; press SW3 to move up or SW4
to move down. Another press on SW2 will stop it.
Solenoid/Clutch Drive
Press the push switch SW2 on the ADF controller PCB to execute the following in
sequence; the operation will end automatically:
Stopper plate solenoid (SL2)
Stopper plate solenoid (SL2)
Pre-reversal solenoid (SL3)
Reversal solenoid (SL1)
Clutch (CL)
4-35