Process code
Example of execution
command
Condition
(A) (B)
Data offset
(A) (B)
Number of bytes of
data (A) (B)
Comparison data
(A) (B)
Operator
Output parameter
* The communication judgment condition DS performs the process only when the status flag becomes "1" ("CW" and "MD" only).
<Response>
Command
Termination
Retrans-
code
code
mission
"00"
"SE"
flag
Even if no condition is specified (e.g., OUT1/2 is "1 condition judgment", there is no output to "OUT2 RS-232C" etc.), send an uncon-
ditional symbol ("X") according to the format (underlined in the data string below). If this symbol is not sent, a format error (14) occurs.
Sent data string: "SE00RDRAH1001010, = 080400000001 + XX, 0500, ER00000000 + XX, 0000, XX + XX, 0000"
Specifies an operation to be executed in the operating condition.
"00": Setting
"10": Read
Specifies a command to be executed according to the following conditions.
Condition 1: A command can be specified by a communication command only.
Condition 2: The communication designation is "RA" and "RI" only.
Condition 3: The number of written bytes is a maximum of 8 bytes (for both of ASCII and
hexadecimal).
Communica-
"OK": Communication OK. "ER": Communication NG. "DS": Data status.
tion judgment
"AL": Always. "xx": Nil.
Data judgment
"= =": Judgment data matched. "! =": Judgment data unmatched.
"> =": Judgment data or more. "< =": Judgment data or less.
The data judgment can be used by an execution command "RD" or "CW".
Condition is
Specifies an offset value of area used for judgment in read data string.
data judgment
Available designation range is between 00h and 7Fh.
Condition is
Specifies the number of bytes which performs judgment.Available desig-
data judgment
nation range is between 01h and 04h.
Condition is
Specifies a comparison data for data judgment.
data judgment
Condition is
Error code designation. If "00000000" is specified, process is executed
"ER" judgment
when any error occurs.
Example: "707A0000" Communication error and address error.
Operator for the condition A and condition B.
"&": AND, "+": OR
Specifies the output ON time in millisecond assuming that a process method is output.
1 to 9999 millisecond. Continued to the next judgment (0000 is specified).
Fixed to "0000" in the RS-232C output part.
Status
flag
5-8 Controller Control Command
5-21