4-1 Communication Designation Function
PI designation:
In the polling designation (PI), similarly with RI, processing is repeated until the processing is terminated by a command process abort
command (AA). However, no response is made after the communication with one tag is ended. Response is returned by a polling query
(PC) command instead. Use this designation when several controllers are connected to a host device through RS-485 etc. (Commercial
232C/485 converter is required.)
PI designation command
Host → Controller
Host ← Controller
Controller ↔ Tag
External input
To use the communication designation of SI, RI and PI, turn ON (trigger input) the dip switch 3-1.
4-4
PC command
Response*
Response*
(No communication)
(Acceptance)
Waiting for input
Correct Usage
PC command
Response*
(Result of communication)
Communication
End of process