Rear Panel Components

The following sections list the rear panel components on the NX-series controllers.
FIG. 14 displays the rear panels of the NX-series controllers.
FIG. 14
NX-series controllers (rear panels)

Serial Ports

The NX-series controllers each feature device control serial ports that support either RS-232 or RS-232, RS-422, and
RS-485 communication protocols. Each port supports the following specifications:




RS-232 Ports

The RS-232 ports (ports 2-4 and 6-8 on the NX-3200/4200; ports 2-4 on the NX-2200; port 2 on the NX-1200) are 5-pin
3.5 mm mini-Phoenix (male) connectors used for connecting A/V sources and displays. These ports support most
standard RS-232 communication protocols for data transmission.
FIG. 15 displays the RS-232 ports for the NX-series controllers.
FIG. 15
RS-232 ports
The following table lists the pinouts for the RS-232 ports.
RS-232 Port Pinouts
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
In the above table, pin 1 is located on the right side of the port, and the pinouts count up to the left.
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers
XON/XOFF (transmit on/transmit off)
CTS/RTS (clear to send/ready to send)
300-115,200 baud rate
NX-3200/4200
GND
RXD
TXD
CTS
RTS
NX-2200
Wiring and Connections
NX-1200
24