Wiring The Rear Panel; Preparing/Connecting Captive Wires; Wiring Guidelines; Using The Axlink Connector For Data And Power - AMX AXB-TM5 Instruction Manual

Amx corporation axb-tm5 television manager instruction manual
Hide thumbs Also See for AXB-TM5:
Table of Contents

Advertisement

Connection and Wiring

Wiring the Rear Panel

Preparing/connecting captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
Never pre-tin wires for compression-type connections.
Do not connect power to the AXB-TM5 until the wiring is complete. If you are using
power from AXlink, disconnect the wiring from the control system before wiring the
AXB-TM5. If you are using an optional 12 VDC power supply, apply power to the
AXB-TM5 only after installation is complete.
1. Strip 0.25 inch of wire insulation off all wires.
2. Insert each wire into the appropriate opening on the connector according to the wiring
diagrams and connector types described in this section.
3. Do not tighten the screws excessively; doing so may strip the threads and damage the
connector.

Wiring Guidelines

The AXB-TM5 requires 12 VDC power to operate properly. The power can be supplied by the
AMX system's AXlink cable or with an optional 12 VDC power supply. The maximum wiring
distance between the control system and AXB-TM5 is determined by power consumption, supplied
voltage, and the wire gauge used for the cable. The following table lists wire sizes and the
maximum lengths allowable between the AXB-TM5 and the control system. The maximum wiring
lengths are based on a minimum of 13.5 volts available at the control system's power supply.
Wiring Guidelines @ 200 mA
Wire size
18 AWG
20 AWG
22 AWG
24 AWG
If the AXB-TM5 is installed farther away from the control system than recommended in the above
table, connect an external 12 VDC power supply to the two-pin PWR connector on the rear panel.

Using the AXlink connector for data and power

To use the AXlink 4-pin connector for data communication and for power supply, the incoming
PWR and GND cable from the control system must be connected to the AXlink cable connector
going to the control system as sown in the AXlink wiring diagram (FIG. 3).
PWR +
AXP/TX
AXM/RX
GND -
To the AXB-TM5
FIG. 3 AXlink connector wiring diagram
4
Maximum wiring length
586.55 feet (178.78 meters)
371.29 feet (113.17 meters)
231.48 feet (70.56 meters)
145.91 feet (44.47 meters)
PWR +
AXP/TX
AXM/RX
GND -
To the Control system
AXB-TM5 Television Manager