AMX NX-1200 Hardware Reference Manual page 19

Nx-series netlinx integrated controllers
Table of Contents

Advertisement

NX-3200 Specifications (Cont.)
USB Port:
Master LEDs:
ICSLAN LEDs (red):
Serial LEDs (red):
Relay LEDs (red):
IR/Serial LEDs (red): 1 set of 8 LEDs, each of which light to indicate the IR/Serial channels 1-8 are
Digital I/O LEDs
(yellow):
Rear Panel Components:
RS-232 (Ports 2-4,
6-8):
RS-232/422/485
(Ports 1 and 5):
Relays (Port 21):
Digital I/O (Port 22):
IR/Serial
(Ports 11-18):
SDHC Slot:
Configuration DIP
Switch:
ICSLAN Ports:
USB Port:
ID Pushbutton:
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers
1 Type-A USB port for connecting a mass storage device for loading .tkn files, reading
or writing configuration files and log files, or updating the firmware on the unit.
• LINK/ACT (green): Blinks when the Ethernet cables are connected and terminated
correctly. Also blinks when receiving Ethernet data packets.
• STATUS (green): Blinks to indicate that the system is programmed and
communicating properly.
• OUTPUT (red): Blinks when the Controller transmits data, sets channels On and Off,
sends data strings, etc.
• INPUT (yellow): Blinks when the Controller receives data from button pushes, strings,
commands, channel levels, etc.
1 LED which blinks when the RJ-45 cables to port 1 is connected and terminated
correctly. The LED also blinks when receiving LAN data packets.
2 sets of eight LEDs, each of which light to indicate that the corresponding RS-232 ports
(2-4, 6-8) and RS-232/422/485 ports (1, 5) are transmitting or receiving RS-232, 422, or
485 data.
1 set of 8 LEDs, each of which light to indicate the corresponding relay channels (1-8)
are active (closed). These LEDs reflect the state of the relay on port 21.
transmitting control data on the corresponding IR/Serial ports (ports 11-18). The LED
indicator for each IR port remains lit for the length of time that IR/Serial data is being
generated.
1 set of 8 LEDs, each of which light when the corresponding rear I/O channels (1-8) are
active. The LED for each I/O port reflects the state of that particular port.
6 5-pin RS-232 control ports using 5-pin 3.5 mm mini-Phoenix (male) connectors with
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send). Supports
300-115,200 baud.
2 10-pin RS-232/422/485 control ports using a 10-pin 3.5 mm mini-Phoenix (male) con-
nector with XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to
send). Supports 300-115,200 baud.
8-channel single-pole single-throw relay port
Each relay is independently controlled.
Supports up to 8 independent external relay devices
Channel range = 1-8
Each relay can switch up to 24 V
Two 8-pin 3.5 mm mini-Phoenix (male) connectors provide connection to relays
8-channel binary I/O port for contact closure with each input being capable of voltage
sensing. Input format is software selectable with interactive power sensing for IR ports.
8 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz with each
output being capable of two electrical formats: IR or Serial.
8 IR/Serial data signals can be generated simultaneously.
IR ports support data mode (at limited baud rates and wiring distances).
1 SDHC card slot for future use.
The Configuration DIP Switch allows you to set boot-time operations (see the
Configuration DIP Switch section on page 30 for more information.)
1 RJ-45 connector for ICSLAN interface
1 Type-A USB port for connecting a mass storage device for loading .tkn files, reading
or writing configuration files and log files, or updating the firmware on the unit.
1 black ID pushbutton used during boot to revert to factory configuration or factory
firmware. Also used after boot to toggle IP mode between Static and DHCP.
or 28 V
@ 1 A
DC
AC
Overview
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-2200Nx-3200Nx-4200

Table of Contents