TecMate Optimate 6 AmpMatic TM180 Instructions For Use Manual

TecMate Optimate 6 AmpMatic TM180 Instructions For Use Manual

Automatic charger for 12v lead/acid batteries
Hide thumbs Also See for Optimate 6 AmpMatic TM180:

Advertisement

MODEL : TM180
AC : 220 – 240VAC
DC : 5,0A
1 x 12V
+
-
STD / AGM-MF / GEL / CYCLIC CELL
15 - 240Ah (48 hour charge)
Automatic charger for 12V lead/acid batteries
50-60Hz 0,85A
12V
INSTRUCTIONS FOR USE
IMPORTANT: Read completely
before charging

Advertisement

Table of Contents
loading

Summary of Contents for TecMate Optimate 6 AmpMatic TM180

  • Page 1 INSTRUCTIONS FOR USE IMPORTANT: Read completely MODEL : TM180 before charging AC : 220 – 240VAC 50-60Hz 0,85A DC : 5,0A 1 x 12V STD / AGM-MF / GEL / CYCLIC CELL 15 - 240Ah (48 hour charge) Automatic charger for 12V lead/acid batteries...
  • Page 2 LED PANEL LED #1 - AC power present LEDs #5, 6 & 7 LED #2 - Battery connected Flashing: Testing in reverse polarity (no charge delivered) Single flash: initial test LED #10 - 5A charge current Double flash: 12 hour test LED #9 - Current between Full on: Maintenance...
  • Page 3 AUTOMATIC DIAGNOSTIC CHARGER FOR 12V LEAD-ACID BATTERIES FROM 15Ah TO 240Ah, AS FOUND IN: DO NOT USE FOR NiCd, NiMH, Li-Ion OR NON-RECHARGEABLE BATTERIES. Charge rate: 5 Ah / hour, will recharge a 240Ah battery in 48 hours. Input: 220-240V maximum 0,85A.
  • Page 4 example, with white matter between the plates, plates touching). If mechanical defects are apparent do not attempt to charge the battery, have the battery professionally assessed. 5. If the battery is new, before connecting the charger read the battery manufacturer’s safety and operational instructions carefully.
  • Page 5 If the assessment is positive the voltage remains limited at 16V and the DESULFATE LED #3 remains on. If the assessment is negative, typically for a badly neglected battery that has not received any charge for many months, the second more powerful TURBO stage will engage with the voltage limit reset to 22V. TURBO RECOVERY mode is indicated by a fl...
  • Page 6: Charging Time

    itself, even a partly damaged battery may initially retain suffi cient power, but lose power faster than normal there-after) or higher than expected power loss through the vehicle’s electrical system. The extend test will end after 11 ½ hours, or the moment the battery voltage falls below 12,4V (YELLOW LED #8). At the end of the extended voltage retention test the LED(s) fl...
  • Page 7: Limited Warranty

    © 2010 TecMate International OptiMate 6 and the names of other battery care products mentioned in these instructions such as BatteryMate, TestMate and TestMate mini, are registered trademarks of TecMate International NV. More information on TecMate products can be found at www.tecmate.com.
  • Page 8 MOUNTING NOTICE 4,5mm L +20mm 2m max. 2m + SAE-73 (2,5m) = 4,5m max.
  • Page 9 Discover our full range of accessories at optimate1.com...

Table of Contents