If you want to add a server blade, you must first remove the dummy module from
the corresponding slot.
1
Figure 35: Removing a server blade dummy module
Ê Release the locking mechanism of the ejecting handles by pressing the
touch points on the inside of both handles (1) simultaneously. The ejecting
handles of the dummy module will be disengaged.
Ê Swing up the upper handle and swing down the lower handle simultaneously
(2) until the locking mechanism of the dummy module disengages and the
dummy module ejects.
Ê Remove the dummy module completely from the slot (3).
V
CAUTION!
Keep the dummy module for future use. If the server blade is removed
and not replaced with a new server blade, then the dummy module must
be reinstalled for cooling, to comply with the applicable EMC regulations
(regulations on electromagnetic compatibility) and for fire protection.
PRIMERGY BX600 S2 Basic Unit
Adding a Server Blade to the System
2
3
77