Panasonic KX-TCA256X Service Manual page 37

Dect portable station
Table of Contents

Advertisement

Items
(I)* Transmitted Power Con-
firmation
(J)* Modulatoin Check and
Adjusment
(K) Frequency Offset Confir-
mation
(L) Frequency Drift Confir-
mation
(M) Sensitivity
Receiver
Confirmation
Adjustment
Point
TP601
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030408
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL=-80dBm
2. Execute the command "regcmd60 01 02 03 04 08".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at TP601 is 20dBm~25dBm.
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the B-Field Modulation is 360kHz/div~380kHz/div using data
type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command "Readmod"
and "wrtmod xx", where xx is the value.)
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the frequency Offset is < ± 45kHz.
-
Follow steps 1 to 3 of (I) above.
4.Confirm that the frequency Drift is < ± 30kHz/ms.
-
Follow steps 1 to 3 of (I) above.
4.Set DECT tester power to -88dBm.
5.Confirm that the BER is < 1000ppm.
Procedure*
37
KX-TCA256X
Check or
Replace Parts
IC201,
IC601,
IC602,
IC603,
FIL601,
C665,C661,
L618, D601,
C654,L616,
R625,C657,
L615,L614,
C656,L610,
C653,L611,
C650,C646,
R623,C642,
C643,C645,
R633,R634,
R645,L619,
C662,L617,
L605,L603,
R615,L612,
L620
IC201,
IC601
IC201,
IC601,
IC602,
IC603,
FIL601,
C665,C661,
L618, D601,
C654,L616,
R625,C657,
L615,L614,
C656,L610,
C653,L611,
C650,C646,
R623,C642,
C643,C645,
R633,R634,
R645,L619,
C662,L617,
L605,L603,
R615,L612,
L620,C608,
R603,C609,
C607,R613,
C606,L601,
L602
IC601,
IC603,
L619,L620,
C662,L617,
C660,R626,
C634,L606,
C633,C632,
L608,C631,
C630,C661,
L618
IC1,IC3,
L2,C54,
C60,C61,
C62,C63,
C64,C65,
C66,C67,
C69,C81,
C82,C56,
R58,R55,
R76