Jackson Conveyor Dishmachines TS-66 Specification Sheet page 6

Traditional series

Advertisement

TS-66 Drawings Rev A.qxd
10/15/04
TS-66 Traditional
Series
Right to Left Operation Shown
Legend to Drawing
A– Machine water inlet 1/2" I.P.S., 180°F minimum, 61-
1/4" above finished floor
B– Electrical connection , approximately 61-1/4" above
finished floor. See table for amperage requirements
C– Drain connection-1 1/2" I.P.S.
D– Prewash water inlet 1/2" I.P.S. 110°F - 140°F
*E–Condensate return connection, 3/4" FPT (return to
boiler feeder or open drain)
*F– Incoming low pressure steam connection, 3/4" FPT
(gate valve supplied)
*Steam tank heat option only
Note: All vertical dimensions are +/- 1/2" from floor due
to adjustable bullet feet
Scrap trough location MUST be a
minimum of 14" from the tub,
regardless of which side the trough
is mounted on.
30-1/2"
24"
18"
All specifications subject to change without notice.
9:52 AM
Page 2
Approximate Total Load Amps
Electric Tank Heat
Steam Tank Heat
Optional 24 KW
Models:
Models:
TS-66 Series
Electrical Data
TS-66
TS-66S
Booster Heater
1-PH
3-PH
1-PH
3-PH
208 Volts 60 Cycles
88.3
51.8
18.3
10.1
230 Volts 60 Cycles
81.5
47.8
18.3
10.1
460 Volts 60 Cycles
N/A
23.9
N/A
5.1
* Option electric boosters come in 3 phase only.
Note: Optional booster heater requires separate electrical connection. 24
KW and 36 KW booster heaters are designed to supply the dishmachine
with rinse water at the appropriate temperature. Models do NOT come
with booster heaters as standard equipment.
10" high backsplash
14"
Drive
Motor
Cover
34"
The maximum recommended distance between any electric
booster heater and the dishmachine is 20 ft.
Optional 36 KW
Electric
Electric
Booster Heater
*3-PH
*3-PH
99.9
66.6
90.4
60.2
45.2
30.1
10-1/2"
21"
OPENING
4" wide x 16" long cutout in vent
cowl/splash shield. Shipped with
cover plates.
Scrap Trough Location
82"
66" TABLE TO TABLE
3"
B
8"
66"
53"
10"
66"
8"
TABLE TO TABLE
74"
82"
Recommended Table Fabrication
20-1/2"
Machine height with doors open is 72".
22"
5"
A
D
61-1/4"
34"
C
5"
E
11-
24"
F
6-1/2"
5-3/4"
4-1/2"
All specifications subject to change without notice.
12-1/2"
4"
26"
8"
4"
Floor sink or drain with
3" minimum drain line.
1"
25"
21"
4"
07610-002-97-65A 8/04