Clearances To Combustibles - Bryant 340AAV Installation, Start-Up, And Operating Instructions Manual

4-way multipoise fixed-capacity condensing gas furnace
Table of Contents

Advertisement

WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in electrical shock,
fire, personal injury, or death.
Improper
installation,
adjustment,
maintenance, or use can cause carbon monoxide poisoning,
explosion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified
installer, service agency, local gas supplier, or your distributor
or branch for information or assistance. The qualified installer
or agency must use only factory-authorized and listed kits or
accessories when modifying this product.
335122-201 REV. B LIT TOP
Fig. 3 - - Clearances to Combustibles
alteration,
service,
The 340AAV Multipoise Condensing Gas-Fired Furnaces are
CSA (formerly AGA and CGA) design-certified for natural and
propane gases (see furnace rating plate) and for installation in
alcoves, attics, basements, closets, utility rooms, crawlspaces, and
garages. The furnace is factory-shipped for use with natural gas.
A CSA listed gas conversion kit is required to convert furnace for
use with propane gas.
See Fig. 3 for required clearances to combustibles.
Maintain a 1-in. (25 mm) clearance from combustible materials to
supply air ductwork for a distance of 36 in. (914 mm)
horizontally from the furnace. See NFPA 90B or local code for
further requirements.
- - 5 - -
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.
A08435