Bryant 340AAV Product Data

Bryant 340AAV Product Data

4-way multipoise fixed-capacity condensing gas furnace

Advertisement

340AAV
4-Way Multipoise Fixed-Capacity Condensing Gas Furnace
Sizes 040 thru 140
The model 340AAV Multipoise Condensing Furnace is specifi-
cally designed to meet the needs of the new construction
market. This high-efficiency furnace utilizes a unique 4-way
multipoise design and compact size to fit where other fur-
naces will not. The model 340AAV can be installed in any of 4
positions including horizontally in attics or crawlspaces, free-
ing space formerly used as a utility or furnace room. Except
for the 140 size, all sizes of the model 340AAV can be
installed in a manufactured (mobile) home when the optional
kit is used. With the exception of the 180 size, all sizes can be
installed with 2-pipe or 1-pipe venting. The 140 size can be
insalled only as a 2-pipe system. Sidewall or through-the-roof
venting options and the use of PVC pipe eliminate the need
for dedicated chimneys or chaseways to facilitate furnace
venting. Time-saving installation features yield a very cost
effective way to provide new home buyers with a high-effi-
ciency and high-quality home comfort system.

FEATURES

3-Pass Primary Heat Exchangers —This design accelerates
heat transfer and extracts heat that conventional heat exchang-
ers waste up the flue. The primary heat exchanger is made of
aluminized steel for corrosion resistance.
Combustion Air and Ventilation—The 340AAV advanced
design allows Schedule 40PVC, PVC-DWV, SDR-21 PVC,
SDR-26 PVC (not approved in Canada), ABS-DWV, or ABS-
F628 Schedule 40 pipe to bring outdoor air into the furnace for
combustion. The extracted heat lowers the temperature of the
Product Data
combustion products to a point (typically below 115°F) that any
of the approved types of pipe can also be used for venting
combustion products outside the structure. The combustion-air
and vent pipes can terminate through a side wall or through the
roof when using 1 of our approved vent termination kits.
Flow-Through Secondary Heat Exchangers—Each cell is
laminated with our patented Everlastic
greater resistance to corrosion. This breakthrough in heating
technology helps extend the life of the furnace for years of
dependable performance. The heat exchanger is positioned in
the furnace to extract additional heat from the combustion
products regardless of furnace orientation.
Perfect Light™ Igniter—Bryant's unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further
enhances the reliability of 340AAV gas furnace and continues
Bryant's tradition of technology leadership and innovation in
providing a reliable and durable product.
Warranty—Limited Lifetime Warranty on the heat exchangers
for the lifetime of original owner in single family residence; 20
years in other residential and commercial applications. 5 year
Limited Warranty on entire unit.
Control Center—The printed-circuit board and all internal wir-
ing are factory installed. Convenient terminals permit quick-
connection of a thermostat and air conditioning control circuits.
Connections for a humidifier and air cleaner are also provided.
A05086
4-Way Multipoise Design—Allows a model 340AAV to be
installed in an upflow, downflow, or horizontal orientation.
The model 340AAV is available in 12 heat/airflow combinations,
and when combined with the 4-way design, allows for 48 different
applications. Factory configured for upflow application, this furnace
can easily be made ready for downflow or horizontal installations.
Direct or Non-direct Venting—The 340AAV can be installed
as a 1 pipe/Non-Direct vent or 2 pipe/Direct vent furnace
except the 140 size which can be installed as 2-pipe only. This
provides added flexibility to meet diverse installation needs.
Insulated Casing—Foil-faced insulation in the heat exchanger
section cuts heat loss. The casing also has the required open-
ings for left- or right-side connection of gas, electric, drain, and
vent connections.
Certifications—The 340AAV units are CSA (A.G.A./C.G.A.)
design certified for use with natural and propane gases, as well
as GAMA efficiency rating certified. The furnace is factory-
shipped for use with natural gas. A CSA (A.G.A./C.G.A.) listed
gas conversion kit is required to convert furnace for use with
propane gas. The model 340AAV meets California Air Quality
Management District emission requirements. Except for the
140 size unit, all 340AAV models can be installed in a manu-
factured (mobile) home when the optional kit is used, and in
elevations up to 10,000 ft (140 size unit limitation of 7,000 ft).
Quality Registration—The 340AAV is engineered and manu-
factured under an ISO 9001 registered quality system.
TM
polypropylene for

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 340AAV

  • Page 1 This high-efficiency furnace utilizes a unique 4-way multipoise design and compact size to fit where other fur- naces will not. The model 340AAV can be installed in any of 4 positions including horizontally in attics or crawlspaces, free- ing space formerly used as a utility or furnace room. Except...
  • Page 2 —2—...
  • Page 3: Clearance To Combustibles

    This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
  • Page 4 * Model HP and 2S thermostat must be field converted to air conditioner operation. **Dual Fuel thermostat is used with furnace and heat pump application ***Thermidistat Control can be configured for multiple use and staging, it must be configured for each specific application.
  • Page 5: Specifications

    UNIT SIZE RATINGS AND PERFORMANCE Input Btuh* Output Capacity Direct Vent (2-Pipe) BTUH* (ICS) (Shaded capacities are specified on rat- ing plate) Non-Direct Vent (1-Pipe) AFUE% Direct Vent (2-Pipe) Nonweatherized ICS Non-Direct Vent (1-Pipe) Certified Temperature Rise Range °F Certified External Static Pressure Airflow CFM‡...
  • Page 6 UNIT SIZE RATINGS AND PERFORMANCE Input Btuh* Output Capacity Direct Vent (2-Pipe) BTUH* (ICS) (Shaded capacities are specified on rat- ing plate) Non-Direct Vent (1-Pipe) AFUE% Direct Vent (2-Pipe) Nonweatherized ICS Non-Direct Vent (1-Pipe) Certified Temperature Rise Range °F Certified External Static Pressure Airflow CFM‡...
  • Page 7 ‡‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. *** Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5, CK5, or KCAKC cased coil is used.
  • Page 8 COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications DIRECT VENT (2-PIPE) ONLY UNIT SIZE ALTITUDE (FT) TERMINATION (BTUH) TYPE 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000 Concentric 2 Pipe or 2-in 80,000 Concentric 0 to 2000...
  • Page 9 COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) Applications MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) DIRECT VENT (2-PIPE) ONLY UNIT SIZE ALTITUDE (FT) TERMINATION (BTUH) 2 Pipe or 2-in 40,000 Concentric 2 Pipe or 2-in 60,000 Concentric 2 Pipe or 2-in...
  • Page 10 3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
  • Page 11 * Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in Maximum Allowable Pipe Length table. † Insulation thickness based on R value of 3.5 per in. FURNACE BLOWER SHELF DOOR...
  • Page 12 † Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum. NOTE: See furnace Installation Instructions when venting multiple furnaces near each other.
  • Page 13 RETURN-AIR UNIT SIZE SUPPLY SPEED 1 side High 024040 Med-Low bottom High 1 side Med-High 036040 Med-Low bottom 1 side High 024060 Med-Low bottom High 1 side Med-High 036060 Med-Low bottom High 1 side Med-High 048060 Med-Low bottom High 1 side Med-High 036080 Med-Low...
  • Page 14 AIRFLOW ELECTRONIC AIR CLEANER COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION HUMIDIFIER A/C COIL VENT PIPE A/C COIL HUMIDIFIER FRONT OF FURNACE VENT COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION AIRFLOW FRONT OF FURNACE —14— GAS-FIRED WATER HEATER A05064 OUTDOOR...
  • Page 15 COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) VENT PIPE ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIRFLOW COMBUSTION - AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION) REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW FURNACE CONDENSATE COMBUSTION–AIR PIPE DIRECT VENT/2-PIPE APPLICATION)
  • Page 16 Furnace shall have reusable-type filters. Filter shall be ______ in (x) ______in. ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications or designs without notice and obligations Casing Casing shall be of .030 in.