Clearances To Combustibles; Electrostatic Discharge (Esd) Precautions - Bryant 351DAS Installation, Start-Up & Operating Instructions

Downflow manufactured (mobile) and modular home direct-vent condensing gas furnace a series
Hide thumbs Also See for 351DAS:
Table of Contents

Advertisement

This forced air furnace is equipped for use with natural or propane gas at altitudes 0 - 10,000 ft (0 - 3,050m).
This furnace is for indoor installation in a manufactured (mobile) or modular home.
This furnace may be installed on combustible flooring in alcove or closet at minimum clearance from combustible material.
This appliance requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC,
PVC-DWV, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is
maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).
Furnace must be installed level, or pitched forward within 1/2 inch of level for proper drainage. Failure will result
in equipment or property damage.
MINIMUM INCHES CLEARANCE TO
COMBUSTIBLE CONSTRUCTION
DOWNFLOW POSITION:
Mimimum front clearance for service 30 inches (762mm).
*
For installation on combustible floors only when installed on special base No. KGASB0201ALL,
Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.
MANUFACTURED MOBILE HOME STANDARDS
This furnace must be installed in accordance with the manufacturer's instructions and Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 or, when such standard is not
applicable, the ANSI A225.1, Standard for Manufactured Home Installation (Manufactured Home Sites,
Communities and Set-Ups), or the Mobile Homes Standard CAN/CSA-Z240 MH Series-M86.
This furnace must be installed with a direct vent (combustion air and flue) system, and use a factory
accessory termination kit.
Condensate Trap
on LEFT Side
COLLECTOR BOX
DRAIN TUBE
CONDENSATE TRAP
INDUCER HOUSING
DRAIN TUBE
BURNER ENCLOSURE
PRESSURE REFERENCE
TUBE ASSEMBLY
personal injury or death. WARNING signifies hazards which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
INSTALLATION
TUBE ROUTING
CAP / PLUG
LOWER COLLECTOR
BOX PRESSURE TUBE
UPPER COLLECTOR
BOX PRESSURE TUBE
GAS VALVE
1. All tubing must be connected securely and routed to avoid kinks and traps.
NOTE:
Fig. 2—Clearances to Combustibles
—3—
This furnace is approved for
DOWNFLOW installation.
0"
B
A
C
K
0"
Clearance in inches
BURNER ENCLOSURE
PRESSURE
REFERENCE TUBE
ASSEMBLY
COLLECTOR BOX
DRAIN TUBE
INDUCER HOUSING
DRAIN TUBE
DRAIN TUBE
COUPLING

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

CAUTION: Electrostatic discharge can affect electronic
components. Take precautions during furnace installation
and servicing to protect the furnace electronic control.
Precautions will prevent electrostatic discharges from
personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing
the control to electrostatic discharge by putting the
furnace, the control, and the person at the same electro-
static potential.
LEVEL (0")
TO
1/2" MAX
FRONT
DOWNFLOW
1"
0"
S E
R V
I
C
*
E
F R
30
O N
T
MIN
3"
0"
Condensate Trap
on RIGHT Side
CAP / PLUG
LOWER COLLECTOR BOX
PRESSURE TUBE
UPPER COLLECTOR BOX
PRESSURE TUBE
GAS VALVE
COLLECTOR BOX EXTENSION DRAIN
TUBE
DRAIN TUBES ROUTED IN
FRONT OF GAS VALVE
CONDENSATE TRAP
324997-201 REV. A / LIT