CONSERVER 24LT CAM TIMER OPERATION INSTRUCTIONS (CONTINUED)
SETTINGS: The left side of cam 5 must be set to drop in just past the stop point of the off/drain cam. There must be a dwell between
the off/drain and the fill, so that the fill will not run while the machine is in the off state.
Any adjustment made to the fill should be made with the right side of cam 5. Proper water level will be achieved when the water touch-
es the bottom of the strainer pan.
CAM 6: Cam 6 is an adjustable cam and controls the sanitizer pump.
FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open by the
cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 6 must be set to drop in just past the starting point of the fill cam. The adjustment for sanitizer volume
must be made with the right side of the cam.
CAM 7: Cam 7 is an adjustable cam and controls the detergent pump.
FUNCTION: The detergent pump cam works off the normally closed contacts of cam 7. This requires the switch to be held open by the
cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 7 must be set to drop in just past the starting point of the wash cam. The adjustment for detergent vol-
ume must be made with the right side of the cam.
CAM 8: Cam 8 is an adjustable cam and controls the rinse aid pump.
FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 8. This requires the switch to be held open by the
cam and allowed to drop into the notch to operate the pump.
SETTINGS: The left side of cam 8 must be set to drop in just past the starting point of the fill cam.