Hide thumbs Also See for NE-C28-E:

Advertisement

Compressor Nebuliser
NE-C28-E
Model
• Instruction Manual
• Mode d'emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
• РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
TM
IM-NE-C28-E-05-03/2010
EN
FR
DE
IT
ES
NL
RU
AR
1649767-8D

Advertisement

Table of Contents
loading

Summary of Contents for Omron NE-C28-E

  • Page 1 Compressor Nebuliser NE-C28-E Model • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ IM-NE-C28-E-05-03/2010 1649767-8D...
  • Page 2: Table Of Contents

    Before using the unit Contents Before using the unit Introduction ....................3 Intended use ....................3 Important safety instructions ..............4 1. Know your unit ..................7 2. Guide to using the Comp Air ..............9 Operating instructions 3. Preparing the nebuliser for use ............10 4.
  • Page 3: Introduction

    Introduction Thank you for purchasing the OMRON Comp Air. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebuliser. When the air enters the nebuliser, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.
  • Page 4: Important Safety Instructions

    Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.
  • Page 5 Important safety instructions • Do not immerse the main unit in water or other liquid. • Do not use or store the device in humid locations, such as a bathroom. • Do not operate the unit with a damaged cord or plug. •...
  • Page 6 • Plug the device into the appropriate voltage outlet. Do not overload power outlets or use extension cords. • Do not wind the power cord around the main unit. • Changes or modifications not approved by OMRON Healthcare will void the user warranty. General Safety Precautions: •...
  • Page 7: Know Your Unit

    1. Know your unit Rear View A. Compressor (Main Unit) D. Inhalation Attachments A1.Power Switch D1.Mouthpiece A2.Air Connector D2.Adult Mask (PVC) A3.Filter Cover D3.Child Mask (PVC) (* Air filter inside.) A4.Nebuliser Kit Holder D4.Nosepiece A5.Ventilation Slots E. Nebuliser Kit A6.Power Cord E1.Cap A7.Power Plug E2.Inhalation Air Inlet...
  • Page 8 1. Know your unit Accessories F. Spare Air Filters x 5 H. Instruction Manual G. Carrying Bag I. Warranty Card Material of attachment Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Polypropylene Child Mask (SEBS): Adult Mask (PVC), Child Mask (PVC): Adult Mask (SEBS), Child Mask (SEBS): SEBS Air Tube: PVC and Polypropylene...
  • Page 9: Guide To Using The Comp Air

    2. Guide to using the Comp Air Preparing the Nebuliser for Use (Section 3) Note: Clean and disinfect the nebuliser kit and applicable inhalation attachments before using the device for the first time, or if it has not been used for more than one week. Taking Medication (Section 4) Notes: •...
  • Page 10: Operating Instructions

    Operating instructions 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device.
  • Page 11 3. Preparing the nebuliser for use Remove the vaporiser head from the medication tank. Add the correct amount of prescribed medication to the medication tank. Caution: The capacity of the medication tank is 2 to 7 ml. Note: Scales on the nebuliser kit are for reference only.
  • Page 12 3. Preparing the nebuliser for use Attach the desired inhalation attachment, as described below. Attaching the mouthpiece Make sure you also attach the cap, when using the mouthpiece. Attach the cap to the inhalation air inlet. Attach the mouthpiece to the inhalation top. Attaching the adult mask (PVC) Attach the mask to the inhalation top.
  • Page 13 3. Preparing the nebuliser for use Attach the air tube. Attach the air tube to the air connector on the compressor. Attach the other end of the air tube to the air tube connector on the medication tank. Notes: • Make sure that the air tube is securely attached to the compressor (main unit) and nebuliser kit, and does not come loose.
  • Page 14: Taking Medication

    4. Taking medication Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. ° Press the power switch to the on ) position.
  • Page 15 4. Taking medication Inhale medication according to your doctor’s and/or health care adviser’s instructions. Using the mouthpiece Prepare your mouthpiece according to Section 3.9. Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. Using the nosepiece Prepare your nosepiece according to Section 3.9.
  • Page 16 4. Taking medication When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Power Plug Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture.
  • Page 17: Care And Maintenance

    Care and maintenance 5. Cleaning and daily disinfecting Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections. Warning: Thoroughly rinse the nebuliser and the mask, nosepiece or mouthpiece with clean hot tap water after each use, and disinfect the parts of the nebuliser kit and applicable inhalation attachments after the last treatment of the day.
  • Page 18: Disinfecting The Nebulising Parts

    5. Cleaning and daily disinfecting If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent.
  • Page 19 5. Cleaning and daily disinfecting Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each Baffle use.
  • Page 20: Maintenance And Storage

    6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor.
  • Page 21: Changing The Air Filter

    Do not boil the air filter cover. Remove the air filter cover, wash it, and make sure it is dry and reattached correctly. • Please contact your OMRON dealer for additional air filters, or if the parts supplied with the device are damaged or missing.
  • Page 22: Troubleshooting

    • If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Return the unit to an authorized OMRON retail outlet or distributor. • The device should be serviced once a year by an approved OMRON service centre.
  • Page 23: Technical Data

    Notes: • Subject to technical modification without prior notice. • This OMRON product is produced under the strict quality system of OMRON Healthcare Co., Ltd., Japan. • The device may not work if the temperature and voltage conditions are different...
  • Page 24 9. Technical data Technical data for the OMRON Comp Air compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Particle Size: *MMAD **approximately 3µm Medication Tank 7 ml maximum Capacity: Appropriate Medication 2 ml minimum - 7 maximum Quantities:...
  • Page 25 This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices. This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: •...
  • Page 26 9. Technical data Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
  • Page 27: Optional Parts And Accessories

    10.Optional parts and accessories Omron V.V.T. Nebuliser Kit Air Tube (PVC, 207cm) Mouthpiece Order No. 9956270-0 Order No. 9956273-5 Order No. 9956268-9 Nebuliser Kit Air Tube (Silicon, 100cm) Nosepiece Order No. 9956269-7 Order No. 9956274-3 Mouthpiece Adult Mask (PVC) Child Mask (PVC) Adult Mask (SEBS) Order No.
  • Page 28 10. Optional parts and accessories Manufacturer OMRON HEALTHCARE Co., Ltd. 24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084, Japan EU-representative OMRON HEALTHCARE EUROPE B.V. Kruisweg 577, 2132 NA Hoofddorp, The Netherlands www.omron-healthcare.com OMRON (DALIAN) CO., LTD. Production facility Economic & Technical Development Zone...

Table of Contents