036-21323-002-C-0206 DESCRIPTION APPLICATION FLEXIBILITY INDOOR Both the outdoor and indoor units are completely piped and B L O W E R M O T O R wired at the factory and are shipped ready for immediate L O C A T I O N A I R O U T installation.
036-21323-002-C-0206 FIGURE 2 - INDOOR PRODUCT NOMENCLATURE YORK INDOOR PRODUCT NOMENCLATURE H A 120 C 0 0 A 2 A A A 1 A Model # Model Number Description Options Product Category H = Air Conditioner Split System E = Heat Pump Split System...
036-21323-002-C-0206 FIGURE 3 - INDOOR PRODUCT NOMENCLATURE YORK INDOOR PRODUCT NOMENCLATURE L A 120 C 0 0 A 2 A A A 1 A Model # Model Number Description Options Product Category L = Air Handling Unit- Cooling F = Air Handling Unit- Heat Pump...
036-21323-002-C-0206 FIGURE 4 - VERTICAL ARRANGEMENTS - LB180 AND LB240 FIGURE 5 - HORIZONTAL ARRANGEMENTS - LB180 AND LB240 CERTAIN BLOWER POSITIONS ARE NOT RECOMMENDED BECAUSE THE BLOWER MOTOR SHOULD NOT BE MOUNTED UPSIDE DOWN. Unitary Products Group...
036-21323-002-C-0206 TABLE 1: UNIT APPLICATION DATA Application Limitations Minimum Maximum Voltage Variation (208/230-3-60) - Volts Voltage Variation (460-3-60) - Volts Voltage Variation (575-3-60) - Volts Ambient Air on Outdoor Coil (Cooling Cycle) - °F Ambient Air on Indoor Coil (Cooling Cycle) - °F TABLE 2: ARI RATINGS - COOLING AND SOUND Cond.
036-21323-002-C-0206 All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request. OUTDOOR UNIT DIMENSIONS Dimensions (In.) Unit 15 Ton 37.5 45.75 110.5 20 Ton 37.5 45.75 128.1 TABLE 8: CONNECTIONS TABLE 9: UNIT CLEARANCES Location Dimensions...
036-21323-002-C-0206 FIGURE 7 - PIPING AND ELECTRICAL CONNECTION LOCATIONS TABLE 11: PIPING AND ELECTRICAL CONNECTION SIZES SIZE CONNECTION ENTRY SUCTION LINE SYS. #1 1-1/8 ID (15 Ton); 1-3/8 ID (20 Ton) LIQUID LINE SYS. #1 5/8 ID SUCTION LINE SYS. #2 1-1/8 ID (15 Ton);...
036-21323-002-C-0206 REFRIGERANT PIPING Suction line velocity for oil return at part capacity, and Liquid line pressure drop due to static head. GENERAL GUIDELINES NOTE: Never base refrigerant line sizes on the OD of the Many service problems can be avoided by taking adequate suction and liquid connections on the unit.
036-21323-002-C-0206 TABLE 23: BLOWER DRIVE DATA Drive Data Unit Model Adj. Motor Pulley Fixed Blower pulley Belts Model Number Blower RPM Range Datum Dia. (In.) Bore (In.) Datum Dia. (In.) Bore (In.) Qty. Designation 1LD0436 640-810 4.0-5.0 1-3/16 LB180 1LD0437 800-1000 5.3-6.3 1-1/8...
036-21323-002-C-0206 TABLE 26: INDOOR UNIT WEIGHTS AND CORNER WEIGHTS Shipping Unit Unit Unit Size Position Operating Weight Length Width 15 Ton Indoor Horizontal 89.5 15 Ton Indoor Vertical 89.5 29.5 20 Ton Indoor Horizontal 1115 20 Ton Indoor Vertical 1115 36.5 NOTE: All dimensions in inches.
036-21323-002-C-0206 FIGURE 13 - LB180 SUPPLY AIR PLENUM DIMENSIONS 1. Shipped knocked down for field assembly FIGURE 14 - RETURN AIR GRILLE FOR LB180 DIMENSIONS Unitary Products Group...