1-14. Settings when Editor is Connected
1-14-1. Settings for Time Code
To set the TIME CODE, use the TC menu in the function menu.
Set the TIME CODE as follows when the editor or the VTR with edit function is connected.
Button
Item
F6
REGENE SOURCE
F7
TCG MODE
F8
RUN MODE
1-14-2. VTR Constant Values Settings of Editor
Set the VTR constant values according to the table 1-14-2 below when the editor which needs the setting
of VTR constant values is connected.
Table 1-14-2. VTR Constant Values Settings of Editor (Standard Value/Hexadecimal)
SRW-5000
VTR CONSTANT 1
Frame rate
1
2
59.94i, 60i, 60P,
20
A0
00
29.97PsF, 30PsF
50i, 50P, 25PsF
21
A0
00
24PsF, 23.98PsF
22
A0
00
SRW-5500
VTR CONSTANT 1
Frame rate
1
2
59.94i, 60i, 60P,
20
A1
00
29.97PsF, 30PsF
50i, 50P, 25PsF
21
A1
00
24PsF, 23.98PsF
22
A1
00
SRW-5000/5500
Setting
int-L
preset
free
Data No.
3
4
5
6
7
8
96
07
07
03
8A
7D
07
07
03
8A
78
07
07
03
8A
Data No.
3
4
5
6
7
8
96
07
07
03
8A
7D
07
07
03
8A
78
07
07
03
8A
VTR CONSTANT 2
Data No.
1
2
3
4
5
6
0D
06
00
00
80
3D
0D
06
00
00
80
3B
0D
06
00
00
80
3B
VTR CONSTANT 2
Data No.
1
2
3
4
5
6
0D
06
00
00
80
3D
0D
06
00
00
80
3B
0D
06
00
00
80
3B
7
8
FF
5A
FF
4B
FF
4B
7
8
FF
5A
FF
4B
FF
4B
1-39