6.8.5

IPMI

SM Error Halt
Specifies the behavior during a system management error or during
configuration changes.
Disabled
A warning message is displayed.
Enabled
Stops and shows Setup entries or a boot prompt.
Load iRMC Default Values
Specifies whether Event Logging is to load the manufacturer's settings
(does not apply to entries that were configured by the BIOS Setup utility).
I
The settings only become effective once you exit the BIOS Setup
by choosing "Save Changes and Exit".
Event Logging does not load the manufacturer's settings.
No
Event Logging loads the manufacturer's settings (does not apply
Yes
to entries that were configured by the BIOS Setup utility).
Event Log Full Mode
Specifies the Event Logging mode.
Overwrite
Event Logging continues despite the SEL being full. The oldest
entry is overwritten.
Maintain
Event Logging is stopped as soon as the SEL (System Event Log)
is full.
SDRR Version
Shows the SDRR version number.
LAN Settings
Calls a submenu for specifying the LAN parameters for the iRMC (see
page
80).
IPMI Status
Calls a submenu for displaying information on the IPMI controller (see
page
81).
BX620 S6
Operating Manual
Server menu
79