Rf Standing Pilot Lighting Instructions - Empire Comfort Systems DVP36FP3 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36FP3:
Table of Contents

Advertisement

RF STANDING PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with
the remote control. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for
gas. Be sure to smell next to the floor because some gas
in heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions. If you can not reach your gas
supplier, call the fire department.
C. Use only the remote control to operate the gas control
1.
STOP! Read the safety information above.
2.
Turn OFF electric power to the appliance.
3.
Open bottom louver assembly.
4.
Turn gas cock counterclockwise
position.
5.
Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
"B" in the safety information above on this label. If you
do not smell gas, go to the next step.
6.
Turn ON electric power to the appliance.
7.
Find pilot - Follow metal tube from gas control. The pilot
is behind the burner on the right side.
8.
Using the remote control, turn main flame to "ON." If the
pilot does not light within 60 seconds, stop and go to Step
5.
1.
Turn off all electric power to the appliance if service is to
be performed (if applicable).
2.
Open bottom louver assembly.
Page 62
LIGHTING INSTRUCTIONS
to "ON"
TO TURN OFF GAS TO APPLIANCE
knob. Never use tools. If valve does not operate, don't
try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
9.
Refer to remote control instructions for detailed information,
control features, and operation. Note: There is a switch on
the side of the Electronic Control Module that allows for
a continuous standing pilot mode or an intermittent pilot
mode. See appliance manual for location of this switch.
If the pilot or burner does not stay lit (in the standing
pilot mode), stop and immediately call a qualified service
technician or gas supplier.
10. If the burner or pilot does not operate properly after
several tries, turn the gas control knob clockwise
to "OFF" and call your service technician or
gas supplier.
11. Close bottom louver assembly.
12. Operation of the gas valve, blower, and/or optional light
must be controlled by using the hand held remote control.
Refer to remote instructions for detailed operation
information.
3.
Locate On/Off gas cock and turn clockwise to
"OFF." Do not force.
4.
Close bottom louver assembly.
31447-5-0214

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents