DVVK-4FV DIRECT VENT TERMINATION KIT

This termination kit can only be used with Empire Comfort Sys-
tems direct vent fireplaces listed for use with DVVK-4FV Vertical
Flex Vent Kit. Please review the instructions packaged with your
fireplace and verify the fireplace model number. Check that this
flex vent system is listed for use with your fireplace model prior to
starting the installation.
This vent kit may be installed as an OEM installation in a
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety stan-
dard, Title 24 CFR, Part 3280 or Standard for Installation in
Mobile Homes, CAN/CSA Z240 MH.
CAUTION
All Fireplaces listed for use with the DVVK-4FV will operate
safely when installed in accordance with this instruction manu-
al. Read all instructions before starting installation, then follow
these instructions carefully to maximize fireplace performance
and safety. Report damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV vent
kit with other gas appliances is not allowed. Do not connect
this appliance to a chimney flue servicing a separate solid fuel-
burning appliance.
WARNING
Failure to follow these instructions may create a possible
fire hazard and will void the warranty.
WARNING
Always maintain minimum clearances around vent systems.
The minimum clearance to combustibles for horizontal runs of
vent pipe is 3 inches from the top, and 1 inch from the sides and
bottom of the vent system. Do not pack the open air spaces
around the fireplace or flue with insulation or other materials.
Any horizontal run must have a 1/4" rise for every one foot of
run towards the vent termination. The vent above the roof must
terminate vertically.
WARNING
Contact your Local Building and Fire Officials about re-
strictions and installation inspections in your area.
Page 32
IMPORTANT SAFETY INFORMATION
The vertical termination cap MUST be vented directly to the
outside. The termination kit MUST NEVER be connected to a
chimney flue(s) servicing a separate solid-fuel burning appli-
ance or any other appliances.
Vertical termination cap MUST NOT be mounted horizontally.
The flexible vent pipe cannot be intermingled with any of the
rigid vent pipe section(s). DO NOT connect two sections of
flexible vent pipe together to achieve a longer length without
the use of approved connectors.
The installation must conform with local codes or in the ab-
sence of local codes, with the National Fuel Gas Code, ANSI
Z223.1 (in the United States) or with the current installation
code CAN/CGA B149 (in Canada).
Only Direct Vent fireplaces approved for use with Empire
Comfort Systems, Inc. DVVK-4FV termination kit shall be
used. See PARTS LIST/ILLUSTRATIONS section for vent
component identification.
Horizontal vent runs must be supported every 2 feet using
wall straps. Vertical runs must be supported every 3 feet using
wall straps. Slip wall straps loosely on to pipe. Attach installer
provided straps to framing members using nails or screws.
The fireplace and venting system should be inspected before
initial use and at least annually by a qualified field service per-
son. Inspect the external vent cap on a regular basis to make
sure that no debris is interfering with the airflow. Inspect entire
venting system to ensure proper function.
Please refer to the fireplace instructions for information on
Termination Cap clearances.
31447-5-0214