Clearances; Mantel & Trim; Alcove - Jøtul GF300 DV IPI Allagash Installation And Operation Instructions Manual

Direct vent gas heater
Table of Contents

Advertisement

Stove and Vent Clearance
Requirements
Minimum Clearances to Combustibles:
See figs. 2-4.
Rear:
2" (51 mm)
Ceiling:
61" (1550 mm)
Corner:
2" (51 mm)
Sides:
3" (76 mm)
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe 2" (51 mm)
Off the sides and bottom 1" (25 mm)
Vertical Run:
All sides
1" (25 mm)
Minimum Ceiling or Alcove Height
Figure 2. Mantel clearances with standard legs.
Reduce stove height and clearance dimensions by 2 1/4
inches with optional Short Legs installed.
Max. Mantel Depth
12.5”
10.25”
8”
5.75”
3.5”
Min. Mantel Depth
Max. Top Trim Depth = 1”
18 1/2”
(419 mm)
Figure 3. Parallel Installation Clearances.
Figure 4. Vent adaptor centerline at minimum clearance
to corner walls.
Alcove Installation
Maximum Alcove Depth:
Minimum Alcove Width:
Min. Alcove Ceiling Height:
With Short Legs (6"): 39 3/4 (1010 mm)
Alcove dimensions result from test
configurations, not stove clearance
specifications.
139495_Rev_C GF 300 DV IPI 9/11/12
24" (610 mm)
36" (914 mm)
42" (1067 mm)
7