General Information - Napoleon LHD50N Installation And Operating Instructions Manual

Natural gas/propane
Table of Contents

Advertisement

If the optional fan or blower is installed, the junction box must be electrically connected and grounded in
accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/
NFPA 70 National Electrical code in the United States.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/HR)
Effi ciency (w/the fan on)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and are
to be expected. Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
There are two switches that control the function of the appliance. One on the receiver that must be placed
in the middle position. The other is on the control module that must be in the "I" position, which denotes
on. If these switches aren't in these locations the appliance will not work, see "REMOTE RECEIVER
INSTALLATION" and "CONTROL MODULE" section.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is equipped with a remote control system, which requires batteries (supplied) to be installed.
The transmitter takes 3 "AAA" batteries and in the case of a power failure the receiver takes 4 "AA" batteries.
LHD50
NG
0-4,500
30,000
24,000
79%
4.5" Water Column
7" Water Column
3.5" Water Column
7
4.1
LP
0-4500
30,000
24,000
79%
11" Water Column
13" Water Column
10" Water Column
W415-0745 / B / 06.08.10

Hide quick links:

Advertisement

Table of Contents
loading