To remove this delay, scan the Delay Length bar code, and set the number of
steps to 0. Scan the Save bar code using the inside the back cover of this
manual.

Interfunction Delay

An interfunction delay of up to 495 milliseconds may be placed between the
transmission of each control character in the message string. Scan the Inter-
function Delay bar code below, then scan the number of steps in 5 millisecond
increments and the Save bar code using the inside the back cover of this man-
ual.
To remove this delay, scan the Interfunction Delay bar code, then set the num-
ber of steps to 0. Scan the Save bar code using the inside the back cover of
this manual.

Intermessage Delay

An intermessage delay of up to 495 milliseconds may be placed between each
scan transmission. Scan the Intermessage Delay bar code below, then scan
the number of steps in 5 millisecond increments and the Save bar code using
the inside the back cover of this manual.
1st Scan Transmission
4 - 8
Prefix
Scanned Data
STX
1
HT
Interfunction Delays
Interfunction Delay
Intermessage Delay
Intermessage Delay
Suffix
2 3 4 5
CR
2nd Scan Transmission