MHSC MJ27NR Installation And Operating Instructions Manual page 15

Unvented gas log heater
Table of Contents

Advertisement

Mantel
Minimum
of 8" Heat
Resistant
Material
FP2002
FP2002
mantel clearances unsafe
86D0024
7"
6"
2
/
"
1
2
4"
8"
Hood
Figure 9 - Minimum Mantel Clearance with Hood - MJ27
(Example of Unsafe Installation)
CLEARANCES and HEIGHT REQUIREMENTS
Figure 9 is an example of an unsafe mantel instal-
lation. This mantel projects 4" at 8" above the opening,
exceeding the maximum acceptable distance of 2
The mantel also projects 7" at 14
exceeding the maximum acceptable distance of 6".
If your mantel profile is unsafe, you may either:
14
/
"
1
2
• Raise the mantel to an acceptable height
OR
• Remove the mantel
1
/
2
1
/
" above the opening,
2