Function Setting - Aiphone AI-900 Operating Instructions Manual

Voice security system
Hide thumbs Also See for AI-900:
Table of Contents

Advertisement

DISTRIBUTED BY: www.leedan.com info@leedan.com Toll-Free: 800-231-1414

2.3. Function Setting

(1) Group call setting
Registers the following contents designating the representative master station/telephone.
Setting Item
Member Station Exchange Number
Member Station line Number
(2) Call forwarding & time-out settings
Registers the following contents designating the exchange number (1 – 16).
Setting Item
Call Forwarding
Time-Based Call Forwarding
Time-Based Call Forwarding Start
Time
Time-Based Call Forwarding End
Time
Busy Call Forwarding
No-Answer Call forwarding
Call Time-Out
Conversation Time-Out
(3) Scan monitor setting
Registers the following contents designating the master station.
Setting Item
Monitoring Time
Monitoring Substation Exchange
Number
Monitoring Substation Line Number Sets the substation equipment number (1 – 64).
Monitoring Substation Number
Monitoring Substation Name
(4) Paging setting
Registers the substations assigned to the zone designating the exchange number (1 – 16).
Setting Item
Zone Number Digit
Paging Time-Out
Zone
Sets the exchange number (1 – 16) of the master station or telephone.
Sets the Line number (1 – 4) of the master station (telephone).
Enable/Disables the Call Forwarding function.
Enables/Disables the Time-Based Call Forwarding function by its start
and end times.
Sets the hour and minute the call forwarding interval will begin. (00:00
– 23:59)
Sets the hour and minute the call forwarding interval will end. (00:00 –
23:59)
Enables/Disables the Busy Call Forwarding function.
Enables/Disables the No-Answer Call forwarding function. If enabled,
calls are transferred when no response is detected within the preset
interval.
Sets the station calling interval (1 – 99 seconds).
Enables/Disables the call time-out function. If enabled, calls are
terminated when no response is made within the preset interval.
Sets the station calling interval (1 – 99 minutes).
Enables/Disables the Conversation Time-Out function. If enabled,
conversations are automatically terminated when the time limit is
reached.
Sets the conversation time limit (10 – 990 seconds).
Sets the scan-monitor time interval (1 – 99 seconds).
Sets the number of the exchange to which the substation is connected
(1 – 16).
Sets the substation number.
Sets the substation name.
Selects the length of the digit to be used to label the paging zone
numbers (1 – 2).
Enables/Disables the Paging Time-Out function.
Sets a Paging time limit (10 – 990 seconds).
Resisters substation numbers (1 – 1024) for each zone.
CHAPTER 5. PC-CONTROLLED FUNCTIONS
Contents
Contents
Contents
Contents
5-3