Electrolux Refrigerator Service Manual page 7

Total no frost fifty sliding door
Hide thumbs Also See for Refrigerator:
Table of Contents

Advertisement

The temperature detection of the cooler compartment is carried out by 1 sensor:
cooler temperature sensor (located inside the air vent grid)
The temperature detection of the freezer compartment is carried out by 1 sensor:
freezer temperature sensor (located inside the freezer cell)
The defrosting of the battery evaporator is controlled by the electronic board through the temperature detection
of the sensors and the detection of the door opening.
Key:
A = cooler temperature sensor
B = freezer temperature sensor
The temperature sensors A and B feature the foamed cable inside the cabinet, therefore they are not
replaceable.
TOTAL NO FROST FIFTY SLIDING DOOR
B
A
7/39