LOCATION

There are several conditions to be considered in
selecting a location for your Stanley Lismore Stove.
a. Position in the area to be heated, central
locations are usually best.
b. Allowances for proper clearances to
combustibles.

FLOOR PROTECTION

It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.
It is recommended that a minimum clearance of
100mm be maintained from the sides and rear of the
appliance to a tiled fireplace or masonry wall, espe-
cially on the right of the appliance as access is
required for the controls. See Fig.16.
FLOOR PROTECTION
100
280
100
100

FLuE LOCATIONS

Flue outlet to suit 152mm (6") internal diameter flue
pipe.
Fig.17
Damper
Lever
Fig.16
9
Flue
Outlet
Air Inlet