[3] Writing the setting data to EEPROM
The settings stored in the EEPROM of the P.C. board for indoor unit servicing are the factory-set values.
Step 1
Push
,
and
SET
CL
∗ In the group control operation, the unit No. displayed for the first time is the header unit No.
At this time, the CODE No. (DN) shows "
and the swing operation starts if it has the louvers.
(The unit No. "
Step 2
Every time when
in order.
(The settings stored in the EEPROM of the P.C. board for indoor unit servicing are the factory-set values.)
Specify the indoor unit No. with its P.C. board replaced to the P.C. board for indoor unit servicing.
(You cannot perform this operation if "
Step 3
Select the CODE No. (DN) can be selected by pushing the
• Set the indoor unit type and capacity.
The factory-set values shall be written to the EEPROM by changing
the type and capacity.
1. Set the CODE No. (DN) to "
2. Select the type by pushing
(For example, Concealed Duct standard type is set to "
Refer to table 2)
3. Push
button.
SET
(The operation completes if the setting data is displayed.)
4. Change the CODE No. (DN) to "
buttons for the temperature setting.
5. Select the capacity by pushing
(For example, 80 Type is set to "
6. Push
button.
SET
(The setting completes if the setting data are displayed.)
NOTE: Setting Concealed Duct standard type Indoor Unit model only
7. Using the set temperature
8. Using the timer time
SET
9. Push
buttons. ( The setting completes if the setting data are displayed.)
CAUTION
Don't remove the materials.
No materials. The power I.C. (IC101) may break.
TEST
10. Push the
(It takes approx. 1 min until the remote controller operation is available again.)
buttons on the remote controller simultaneously for more than 4 seconds.
TEST
" is displayed if the auto-address setting mode is interrupted in [2] step 2 a)
UNIT LOUVER
button is pushed, the indoor unit No. in the group control operation are displayed
10 10 10 10 10
". (without change)
/
buttons for the timer setting.
11 11 11 11 11
" by pushing
/
0012
/
/
buttons, set the data. (0001)
button to return to the normal stop status.
10 10 10 10 10
". Also, the fan of the indoor unit selected starts its operation
" is displayed.)
/
0004
".
/
buttons for the timer setting.
". Refer to table 3)
CE
buttons, set "
" to the CODE No. (DN).
<Fig. 2>
– 60 –
button for the temperature setting.
<Fig. 1 RBC-AMT32E>
00 04
3- 3
3 6 5 1
10
4 2