Location Of Electrical Cord; 110V / 60 Hz Electrical Installation; Testing The Gfci - Coleman Roto Spa Owner's Manual

Spas
Table of Contents

Advertisement

4

Location of Electrical Cord

This applies to 110V systems.
The electrical cord is located inside the equipment
area and must be removed in order to plug in the
spa.
Remove the access panel for the equipment area and
set it aside. (Access panel removal is described on
page 23 .)
Locate the power cord with the GFCI plug. Inspect
the cord for damage before use.
Route the GFCI plug through the access hole located
in front under the access panel area.
Pull the full length of the power cord (15 feet / 4.6 m)
through the access hole.
Replace the access panel. Do not overtighten the
screws.

110V / 60 Hz Electrical Installation

This product is a cord-connected spa with a pump
heater, lighting fi xture, and spa side control. The op-
erating power is 110V AC.
A licensed electrician may be required to upgrade
your standard receptacle and/or circuit breaker. Al-
ways follow applicable local, state and federal codes
and guidelines.
The spa is equipped with a 15 amp GFCI cord and
plug kit.
Plug the spa into a dedicated electrical line with a 15
amp breaker.
Always use a weatherproof-covered receptacle. Re-

Testing the GFCI

Test the GFCI plug prior to fi rst
use and periodically when the spa
is powered.
1.
Plug in the GFCI into the
power outlet. The indicator
should turn on.
1.
Press the TEST button. The
GFCI will trip, the indicator
will turn off, and the spa will
stop operating.
ceptacle shall be located not less than 5 feet (1.5
m) from and not exceeding 10 feet (3.0 m) from the
inside wall of the spa (NEC 680.43(A)).
Do not use extension cords. Using an extension cord
will void your warranty.
Do not bury the power cord. If your cord becomes
damaged, replace it before next usage.
If you need to replace your cord, replace it with a 15
amp GFCI connection. The cord may not be longer
than 15 feet (4.6 m). You can order a replacement
GFCI and cord kit from customer service, part num-
ber ELE09700086.
2.
Press the RESET button. The
GFCI will reset, the indicator
will turn on again, and the
spa will turn back on.
The spa is now safe to use.
If the GFCI trips while the spa is
in use, press the RESET button. If
the GFCI does not reset, unplug
the spa and call your spa dealer
for service. DO NOT USE THE
SPA!