Technical Data - Dimplex KSS 2504 Installation And Operating Instructions Manual

Split air conditioner for wall mounting
Table of Contents

Advertisement

Technical Data

Split room air conditioners with rapid
refrigerant coupling
Indoor unit
Outdoor unit
Cooling capacity / heat output
Air volume, indoor unit
Connection voltage
Nominal power consumption for cooling /
heating
Sound power level, outdoor / indoor unit
(approx.)
Refrigerant
Net weight outdoor / indoor unit
Dimensions, outdoor unit (W x H x D)
Dimensions, indoor unit (W x H x D)
Difference in height between device units,
maximum
Length of refrigerant pipe, maximum
Temperature range, cooling
Indoor unit
(adjustable range)
Outdoor unit
(fixed-setpoint conditions)
Temperature range, heating
Indoor unit
(adjustable range)
Outdoor unit
(fixed-setpoint conditions)
Electrical connection lines
Mains cable
(dimension / length)
Control line
(dimension / length)
Energy efficiency class
Coefficients of performance
4)
heating)
Refrigerant pipe accessories
consisting of a suction and pressure pipe, insulated and pre-filled with refrigerant
Pre-filled refrigerant pipes, length 2.5 m
Pre-filled refrigerant pipes, length 5.0 m
Split room air conditioners for wall mounting
with flanged connections, not for use with KMSL refrigerant pipes
(technical data see above)
Indoor unit
Outdoor unit
Pipe for liquid
Suction gas pipe
Split pipes max. length / max. height
Special accessories
comprising 2 brackets for wall mounting of outdoor unit
Wall bracket
Condensation pump
1)
Nominal data acc. to ISO 5151
2)
Refrigerant pipes may be joined to extend them. The maximum permitted length of pipe must be observed.
3)
In compliance with 92/75/EC, Directive 2002/31/EC
4)
Acc. to EN 14511
1)
3)
(cooling /
3)
(essential)
KSS 2504 AB
KSS 2504 A
KSS 2504AI
KSS 2504AA
kW
2.5 / 2.8
m³/h
420
kW
0.79 / 0.97
dB(A)
52 / 36
kg
32 / 8.5
mm
848 x 540 x 260
mm
770 x 250 x 180
M
M
Upper operating limit +30 °C / lower operating limit + 16 °C
Upper operating limit +43 °C / lower operating limit -5 °C
Upper operating limit +30 °C / lower operating limit +16 °C
Upper operating limit +43 °C / lower operating limit -7 °C
mm²
3 x 1.0 / 5.2 m
mm²
2 x 0.75 / 6.0 m
A
3.2 / 2.9
KMSL 1438A-2
KMSL 1438A-5
KSS 2504A IB
KSS 2504A AB
mm
6 x 1
mm
10 x 1
m
20 / 10
WKS 357
KSI 3100
4
KSS 3204 AB
KSS 3204 A
KSS 3204AI
KSS 3204AA
3.2 / 3.5
460
1/N/PE 230 V
1.09 / 1.24
55 / 39
R 410A
32 / 8.5
848 x 540 x 260
770 x 250 x 180
10
20
3 x 1.5 / 5.2 m
2 x 0.75 / 6.0 m
B
3.0 / 2.8
KMSL 1412A-2
KMSL 1412A-5
KSS 3204A IB
KSS 3204A AB
6 x 1
12 x 1
20 / 10
WKS 357
KSI 3100