6.

Leakage Protection

The anti-flood switch in the base tray will activate the drain pump and drain the water from the tub in
the event of an internal leakage.
If the float switch is activated, all electric components are switched off except the drain pump.
Overflow protection
The filling phase fills up to the level, monitored by a pressure monitor. If the pressure monitor does
not switch in, this filling phase is generally limited electronically to 2 minutes.
If the pressure monitor has not switched in by then, the electronics jump to the error mode "shut off
tap", and the program is stopped.
If the pressure monitor switches back during the cycle, a maximum of 10 sec. further filling is
possible. If the pressure monitor has not switched in by then, the electronics jump to the error
mode "shut off tap", and the program is stopped.

Safety level

If the safety level is reached by over-fillling more than 3,2 litres, floater switch starts the drain
pump.
Safety level
Spares Operation - R.Kurzke 02/05
599 521 951
EN