5-2. RAS-18UKX / RAS-18UAX

0.39m
(Connecting pipe)
12.7
O.D.:12.7mm
P
Packed valve
( 12.7)
Compressor
PH250X3-4LM
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Cross flow fan
Condenser
Muffler
Propeller fan
Outdoor unit
Standard
Pressure P
P
P
P
P
(MPaG)
0.4
0.5
0.3
T
Indoor unit
Evaporator
Surface temp. of heat
exchanger interchanging
pipe T
T (°C)
T
T
T
10.0
13.0
2.0
– 14 –
FILE NO. SVM-01010
0.49m
(Connecting pipe)
6.35
O.D.:6.35mm
Packed valve
( 6.35)
Capillary tube
2.4x1000S
Refrigerant
R-22 1.06 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan Speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15