Toshiba RAS-24UKX Service Manual page 25

Split wall type air-conditioner
Table of Contents

Advertisement

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER
Please make sure certainly that the installation of this air conditioner will be reported to the local power
supplier before installation.
If you have any obscure problems (or if the power supplier does not accept the installation) of this appliance,
service agency will take adequate countermeasures.
Remark per EMC Directive 89/336/EEC
To prevent flicker impressions during the start of the compressor (technical process) following installation
conditions do apply.
1. The power connection for the air conditioner has to be done at the main power supply. This distribution has
to be of an impedance.
Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max.!
2. No other equipment has to be connected to this power line.
3. For detailed installation acceptance please contact with your power supplier, it restriction do apply for
products like washing machines, air conditioners or electrical ovens.
4. For power details of the air conditioner, refer to the rating plate of the product.