MICOM FUNCTION
2. Description of Function
2-1. Funnction of Temperature Selection
Division
Power Initially On
Type-1
-19 °C
(88-LED)
Change
of
Type-2
Indication
(Bar-LED)
Lamp
Temperature
Middle
Control
(-19.0 °C)
Freezer
Control
<-19.0 °C>
(3.5 °C)
Refrigeration
Control
<4.5 °C>
* The temperature can vary ±3 °C depending on the load condition.
1. When power is initially applied or reapplied after power cut, "Medium" is automatically selected.
2. When the temperature selection switch in the freezer and refrigerator compartments is pressed, the light is on in the
following sequence:
"Middle"
"Middle Strong"
3. The temperature setting condition of freezer and refrigerator compartments shall not be indicate in the standard model
(GW-P227, GW-L227, GW-C227, GW-B227) when refrigerator or home bar door is closed.
1st Press
3 °C
2 °C
-22°C
Middle Strong
(-21.5 °C)
<-21.0 °C>
(2.5 °C)
<3.5 °C>
"Strong"
"Weak"
"Middle Weak"
2nd Press
-23 °C
0 °C
-15 °C
Strong
(-22.5 °C)
<-22.5 °C>
<-14.5 °C>
(1.0 °C)
<1.5 °C>
*(
) : P227, L227
*< > : C227, B227
- 17 -
3th Press
4th Press
6 °C
-17 °C
Weak
Middle Weak
(-14.5 °C)
(-16.5 °C)
<-16.5 °C>
(5.5 °C)
(7.5 °C)
<8.0 °C>
<6.0 °C>