11. WARNINGS AND ERROR MESSAGES

If a malfunction occurs, the main menu is switched to and the malfunction is displayed in marquee. The malfunction is acknowledged by pressing
2 seconds.
The button must be depressed until the change in the operating status appears on the display.
Note
If error messages recur directly, customer service is to be notified immediately. In the case of error messages that pose a safety risk, burnback and flue gas
flap is activated and the stove is automatically switched off
Display
STB >I/O<
NO PELLETS >I/O<
FAN DEFECT >I/O<
FLAME SENSOR
DEFECT >I/O<
ROOM SENSOR SIGNAL LOST
>I/O<
SERVICE >I/O<
CALL SERVICE MOTOR
DOOR OPEN >I/O<
AUGER-PMSM
DEFECT >I/O<
Malfunction designation
Safety temperature limiter is activated
No pellets in container
Flue gas blower defective
Flame sensor defective
Rika room sensor reception defective
Pellet amount for cleaning and maintenance
exceeded
Pellet backlog
Door open
Screw motor defective
Cause / remedy
Establish cause of activation; eliminate this and reset using reset button
directly at STB. The error message must then also be acknowledged.
Only with cooled stove.
May also occur on first start (first filling). Check whether there are
sufficient pellets in the container and re-start unit after acknowledging
malfunction.
- Screw conveyor blocked
- Flame sensor sleeve dirty
- Chimney draught too great
Acknowledge the error message.
Acknowledge the error message.
Transmission between the transmitter and receiver has been lost.
If the error message appears again immediately after re-starting the
device, it means either the battery is flat or the component is defective.
Acknowledge the message and perform cleaning or maintenance
procedures (see CLEANING AND MAINTENANCE) durchführen.
Overfilling of the combustion cavity with a subsequent backlog of
pellets in the drop chute has been detected.
The error message can be acknowledged by pressing the
button simultaneously (held until the error message disappears).
Check to make sure the door is closed and that the door contact
switch engages.
(The DOOR OPEN message doesn't need to be acknowledged; the
display will disappear when the door is closed.)
Acknowledge the error message.
for at least
and
MENU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

PicoRevo

Table of Contents