Direct vent gas stove
Table of Contents

Advertisement

Vent Termination Zones - Natural Gas
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
A
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
12 Ft.
(3.65 m)
B
Min. Vertical
8 Ft.
Termination
(2.43 m)
5 Ft.
(1.52 m)
Min. Rise
2 Ft.
(.60 m)
(1.52 m)
• ALL VENTING MUST TERMINATE (END) WITHIN ONE OF
THE SHADED AREAS.
• SET STOVE EXHAUST RESTRICTOR TO THE POSITION
THAT CORRESPONDS TO THE VENT TERMINATION AREA
IN THE DIAGRAM ABOVE.
• ALWAYS MAINTAIN THE PROPER CLEARANCES TO
COMBUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installation
and fuel type, then adjust the restrictor to the corresponding
position as shown in Figure 7, page 9.
Figure 9. Coaxial Vent Termination Window / NG
10
Horizontal and Vertical
Terminations for COAXIAL VENT
Up to four 45° or
two 90° elbows
addition to the
starter elbow.
A
B
C
5 Ft.
10 Ft.
15 Ft.
(3.05 m)
(4.57 m)
HORIZONTAL RUN
permitted in
D
20 Ft.
27 Ft.
(6.09 m)
(8.22m)
Vertical
Termination for
COLINEAR VENT
35 Ft.
35 Ft.
(10.67 m)
(10.67 m)
25 Ft.
25 Ft.
(7.62 m)
(7.62 m)
B
Minimum
Minimum
Vertical
Vertical
Termination
Termination
8 Ft.
8 Ft.
(2.43 m)
(2.43 m)
45°
Elbow
Up
2 Ft.
2 Ft.
(16 cm)
(16 cm)
H O R I Z O N TA L R U N
• VENTING MUST TERMI-
NATE (END) WITHIN THE
SHADED AREA.
• Adjust the Exhaust
Restrictor to position B
for any NG colinear
termination.
Figure 10 . Colinear Termination / NG