Burner Assembly and LP Conversion

The burner assembly consists of the gas valve coils,
gas valve, burner, and inlet pipe.
To convert the dryer from natural gas to LP gas,
the burner assembly must be replaced. The
burner cannot be converted to LP gas. Refer to LP
conversion kit WE25x217.

Gas Valve Coils

The burner assembly has a gas valve that utilizes
3 coils. A double coil (safety and booster coils
combined) and a single main coil are located on top
of the gas valve in front of the combustion chamber
opening. All coils can be replaced separately.
Gas valve coil assembly resistance values:
• Safety coil terminals - 1400 
• Booster coil terminals - 580 
• Main coil terminals - 1300 
To remove the double and main coils:
1. Remove the top panel, front panel, and drum.
(See
2. Remove the Phillips-head screw then pull the
gas valve moisture shield forward.
Gas Valve
Moisture
Shield
3. Disconnect the wire harness from both coils.
Main Coil
4. Note the position of the locator pins inserted in
the coil bracket.
5. Remove the 2 Phillips-head screws that attach
Booster Coil
the coil bracket to the valve body.
Safety Coil
6. Lift the bracket vertically. Lift coils to remove.
Note: Upon reassembly, ensure the locator pins are
inserted into the holes provided in the coil bracket.
– 31 –
Top Panel, Front Panel, and Drum
Disconnect
Locator Pin
Locator Pin
.)