F790
F7A0
F7B0
F800
F810
F820
F90x
F91x
F92x

Induction Failure Codes

Induction Element Locations: 0= Left Front, 1= Left Rear, 2= Right Front, 3= Right Rear
FA00
FA10
FA30
FA40
FA47
FA5x
FA6x
FA7x
FA8x
FA9x
FAAx
Main Logic Board internal touch key Replace Main Logic Board.
chip signal error
Main Logic Board internal touch key Replace Main Logic Board.
chip memory error
Main Logic Board internal touch key Replace Main Logic Board.
chip memory error
Main Logic Board memory error
Main Logic Board memory error
Main Logic Board EEPROM memory
error
Door Lock Unlock-Home signal
became untrue during cooking
Door Lock Lock-Home signal
became untrue during clean
Both the Lock-Home and
Unlock-Home switches are closed
simultaneously
Device not found within Induction
Cooktop module
Induction cooktop – bridge board
error
Induction cooktop – fan error
Induction cooktop – generator
board error
Enable signal not getting from Main
Logic Board J241 pin 8 to Cooktop
Bridge Board X200 pin 3
Induction cooktop burner sensor
too hot (F-code not logged)
Induction cooktop – filter board
error
Induction cooktop generator board
temperature sensor open or DC
problem
Induction cooktop – comm error
from cooktop filter to other cooktop
boards
Induction cooktop – coil
temperature sensor break
Induction cooktop – unsuitable
pot size
Replace Main Logic Board.
Replace Main Logic Board.
Replace Main Logic Board.
a) Lock motor cam switch faulty/loose.
b) Harness from lock motor to RPSM J16 open.
NOTE: Control will open/close relay several
times trying to "jog" the motor.
a) Lock motor cam switch is stuck closed.
Replace assembly.
b) Insulation wrapped around cam.
c) Replace RPSM Main Board.
a) Fix open signal harness within cooktop.
b) Replace filter, bridge or generator board.
Replace induction bridge board.
a) Replace cooktop fan.
b) Replace cooktop bridge board.
Replace both cooktop generator boards.
a) Check harness connection.
b) Replace bridge board.
c) Replace Main Logic Board.
a) Transient error – wait for cooldown.
b) Replace cooktop coil sensor.
a) Check power connections on filter board.
b) L1 or L2 from line is faulty.
c) Replace cooktop filter board.
Replace cooktop generator board.
a) Check signal harness in cooktop module.
b) Replace filter board.
a) Coil sensor harness.
b) Replace cooktop coil sensor.
c) Generator board.
a) Transient error – use correct pot size.
b) Coil fell away from glass.