Tt Functions - Furuno FCR-2107 series Operator's Manual

Marine radar/arpa
Hide thumbs Also See for FCR-2107 series:
Table of Contents

Advertisement

TT functions

Activating/deactivating TT
Put the cursor on the TT setting in the infor-
mation area then push the left mouse button
to select an option
(AUTO or MAN).
AUTO
MAN
Selecting automatic or manual acquisition
1. Select the TT setting and push the right
button.
Manual 100
Auto 25
Auto 50
Auto 75
Auto 100
Ref target vector
Cancel All
2. Choose a Manual or Auto option as
applicable.
3. Push the left button.
Manually acquiring a target
1. With the arrow inside the effective display
area, spin the scrollwheel to show Tgt
Acquire in the guidance box.
2. Use the trackball to put the arrow on the
target you want to acquire.
3. Push the left button to acquire the target.
Terminating tracking a target
1. Spin the scrollwheel to show Tgt
Cancel/L=All in the guidance area.
2. Put arrow on target.
3. Push the right button.
Displaying target data
1. Put arrow on TT target.
2. Push scrollwheel.
To delete the target data, put the arrow on
the target and push the scrollwheel.
TT symbol color, size
1. Left-click Symb DISP at the right side
of the screen.
2. Click the Targets tab.
Color box
Size box
3. Set the arrow in the Color box.
4. Spin the scrollwheel to select color and
push it to confirm selection.
5. Set the arrow in the Size box.
6. Spin the scrollwheel to select size and
push it to confirm selection.
7. Click the Close button.
6
Setting CPA and TCPA ranges
1. Use the trackball to select the CPA setting.
Predictor
OFF
PASTPOSN T 12 min
CPA
1.0 nm
6 min
2. Spin the scrollwheel to select the CPA
setting desired and push the scrollwheel.
3. Use the trackball to select the TCPA
setting.
4. Spin the scrollwheel to select TCPA value
desired and push the scrollwheel.
Setting vector length
1. Spin the scrollwheel to select RelVect.
T VECT(G) or T VECT(S) (whichever is
displayed) at the right side of the screen.
T VECT(G)
12 min
Predictor
OFF
PASTPOSN T 12 min
CPA
1.0 nm
6 min
SINGLE
06.xx 06.xx
2. Spin the scrollwheel to display R VECT,
T VECT(G) or T VECT(S) as appro-
priate.
3. Select the vector time setting.
4. Spin the scrollwheel to display time
desired and push the scrollwheel.
Setting an acquisition zone
An acquisition zone can be used to enable
automatic target acquisition in a specific area.
1. Left-click AZ at the bottom right corner.
2. Set the arrow at the upper left corner of
the acquisition zone and left-click.
3. Drag the arrow to the lower right corner
and left-click.
To erase an acquisition zone, put arrow
on applicable AZ indication and push the
left button until the guard zone disappears.
If two acquisition zones are in use, the No.1
acquisition zone cannot be erased unless
the No.2 acquisition zone is erased.
Acquisition zone
000
350
010
020
340
330
030
320
040
310
300
A
290
B
280
270
260
250
240
230
220
140
210
150
200
160
190
170
180
050
060
070
080
090
100
110
120
130

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcr-2807 seriesFcr-2107-bb series

Table of Contents