8. Enter the IP Address into the TCP/IP Address field. This information is obtained from either
your System Administrator or from the Obtaining the Master's IP Address (using
DHCP) section on page 42.
9. Click OK three times to close the open dialogs and save your settings.
If you are currently connected to the assigned Master, a popup asks whether you
would want to temporarily stop communication to the Master and apply the new
settings.
10. Click Yes to interrupt the current communication from the on-board Master and apply the new
settings.
11. Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System
Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during
the incorporation. Wait until the STATUS LED is the only LED to blink.
12. Press Done once the Master Reboot Status field reads Reboot of System Complete.
13. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The
default System value is one (1).
14. Right-click the associated System number and select Refresh System. This establishes a new
connection to the specified System and populates the list with devices on that system. The
communication method is then highlighted in green on the bottom of the NetLinx Studio
window.
If the connection fails to establish, a Connection Failed dialog appears.
Try selecting a different IP Address if communication fails.
Press the Retry button to reconnect using the same communication parameters.
Press the Change button to alter your communication parameters and repeat
steps 2 thru 10.

Upgrading the new NI Controller firmware via an IP

1. After the Communication Verification dialog window verifies an active communication
between the PC and the Master, verify the NetLinx Integrated Controller appears within the
OnLine Tree tab of the Workspace window (FIG. 32).
FIG. 32 Sample NetLinx Workspace window
NetLinx Integrated Controllers
Configuration and Firmware Update
On-board Master
Sample control cards
NetLinx Integrated Controller
49